Advanced Performance Inject-Aire

Two designs - One solution

The Advanced Performance Inject-Aire Low NOx Burner (API) produces an exceptionally stable flame at all firing rates. Capable of firing natural gas, light oil, heavy oil, digester gas, ethanol, and more, the API-AF offers a wide range of fuel burning capability. Our engineers specifically designed this burner speed up installation, reduce space requirements, and facilitate maintenance when needed. The API burner incorporates VFD for control of FD fan speed, resulting in significant electrical reductions, regardless of the type of fuel burned.

Capacity – 4 MMBTUH – 120 MMBTUH

Fuel – Natural gas, #2-#6 Oil, specialty fuels

NOx Levels – 30 PPM for Natural Gas

Turndown – 10:1 for Natural Gas; 8:1 for #2 oil

Recommended Boiler Type- Firetube, Flextube, Firebox, Cast Iron Sectional, Watertube

Recommended Use  – Commercial or Industrial

 
  • Overview
  • Application
  • Features
  • Documents
Overview

Capable of firing natural gas, light oil, heavy oil, digester gas, ethanol, and more, the API-AF offers a wide range of fuel burning capability. Our engineers specifically designed this burner speed up installation, reduce space requirements, and facilitate maintenance when needed. The API burner incorporates VFD for control of FD fan speed, resulting in significant electrical reductions, regardless of the type of fuel burned.

 
Application

-Recommended Boiler Type- Firetube, Flextube, Firebox, Cast Iron Sectional, Watertube

-Recommended Uses (commercial or industrial) – Commercial or Industrial

Features

Fuel Variety: No 2 through No 6 Fuel Oil, and/or natural gas.

Advanced Design: our engineers specifically designed this burner to eliminate field errors, reduce space requirements, and facilitate maintenance when needed.

Model Options: two models are available: RF is designed for larger capacities and allows for the fan to be placed remotely; the AF is designed for smaller applications and ease of maintenance.

High Efficiency: Incorporates VFT for control of FD fan speed, resulting in significant electrical reductions, regardless of the type of fuel burned

Low emissions: Natural Gas: Sub 9 ppm without FGR

Specification: Single burner: firetube, firebox(cast iron sectional), watertube boilers or HTHW generators

NOx Emissions: Natural gas: Less than 9 ppmc No. 2 Fuel oil: less than 90ppmc (maximum 0.01% FBN) without FGR. No. 6 fuel oil: less than 250 ppmc (maximum 0.3% FBN) without FGR.

Burner Efficiency:

Operation: Turndown: 10:1 on gas firing; 8:1 on oil firing.

Supply Pressure: The API burner accommodates a wide variety of combustion applications and fuels. Specific information relating to fuel intended to be used, as well as pressure and temperatures, must be provided.

Burner Control and Monitoring: Parallel/full metering firing rate control: any Preferred controller. Oxygen sensor: Model «ZP» In-Situ sensor, reliable zirconia oxide detector. Monitoring: SCADA/Flex remote monitoring and control system. Instruments: Standard and Optional equipment

Documents

Advanced Performance Inject-Aire Specification

Advanced Performance Inject-Aire Brochure

 

Advanced Performance Inject-Aire Brochure (Español)

 

SUBSCRIBE TO OUR MAILING LIST